¹°»ù°ü¼öÀÚÀç ¿µ¾î ¹°»ù°ü¼öÀÚÀç Çѱ¹¾î  
¡Ü Home | Products | Fogs

 




Applications
¡Ú Misting and irrigation over benches
¡Ú Minimum heigh¢ªt :1m
¡Ú Maximum spacing between lateral¢ª : 0.9m
¡Ú Controlling humidity and temperature
¡Ú Maximum spacing between lheads¢ª : 0.9m
¡Ú Maximum distance of lateral from bench to edge¢ª : 0.1m
  rote 0 : It is applied for the seedong and propagation system


Features
¡Ú Three size intra-filtering structures such as 0.4, 0.6 and 1mm
¡Ú No dripping during operation
¡Ú Perfect threaded union
¡Ú Fine mist without drifting of water droplets below 1.5 bar
¡Ú Having rooms for debris in intra-structures
¡Ú Particle size : 71§­(2bar), 66§­(3bar)
¡Ú Uniform coverage

 



Applications
¡Ú Controlling humidity and temperature
¡Ú Providing good conditions for plant raising


Features
¡Ú Three size intra-filtering structures such as 0.4, 0.6 and 1mm
¡Ú PE and PVC connrctions
¡Ú Perfect threaded union(1 or 2 emitters) with anti-drainage(blue)
¡Ú Filtering requirement : 130 micron ( 120 Mesh No.)
¡Ú Bayonet assembly(4 emitters) with anti-drainage(black)
¡Ú Having rooms for filtered debris in intra-structures
¡Ú Anti-drainage are avaiable
¡Ú Uniform coverage
¡Ú Fine droplet size


Table3. Fogger flow rate (§¤/hr) according to the applied pressure
Division Green Blue White
Pressure(bar) 1 20 - -
2 29 4.5 13.4
3 33 5.4 16.0

Table 4. Micro fogger technical data of MSF
Model Applied pressure at 2bar Applied pressure at 3bar
Flow rate(§¤/hr) Average droplet size(§­) Flow rate(§¤/hr) Average droplet size(§­)
MSF/T-10 9.0 68 10.8 65
MSF/F-20 18.0 21.6
MSF/T-20 26.8 67 32.0 64
MSF/F-40 53.6 56.0

Table 5. Micro fogger applications and recommended spacing1
Model For climate control (Cooling & humidifying) For pesticide spraying For propagation2
MSF/T-10 1.5¡¿3.0 m
2.0 ¡¿4.0m
1.5¡¿3.0m -
MSF/F-20 3.0¡¿3.0m
2.0¡¿4.0m
- 1.0¡¿1.0m
MSF/T-20 1.5¡¿3.0m
2.0¡¿4.0m
1.5¡¿3.0m -
MSF/F-40 3.0¡¿3.0m
2.0¡¿4.0m
- 1.0¡¿1.0m

¡Ø note 1 : Distance between heads ¡¿ distance between laterals, note 2 : At 1.0m height above table/plants





Applications
¡Ú Controlling humidity and temperature
¡Ú Spraying chemicals


Features
¡Ú Three size intra-filtering structures such as 0.4, 0.6 and 1mm
¡Ú Having rooms for filtered debris in intra-structures
¡Ú Filtering requirement : 130 micron ( 120 Mesh No.)
¡Ú Recommendable operation pressure ranges from 3 to 8 bar
¡Ú Anti-drainage are avaiable
¡Ú Extra fine droplet size
¡Ú Flow rate 9.8 §¤/hr @ 4~5 bar

 




Applications
¡Ú
Spraying chemicals
¡Ú
Phytosanitary
¡Ú
Vaccination
¡Ú
Reduction of odor
¡Ú
Dust suppression
¡Ú
Static electricity control
¡Ú
Foliar treatment
¡Ú
Disinfectant

Features